Libra S80 with Printer & Bluetooth. Stand alone, Variable Bandwidth, European Pharmacopoeia compliant scanning UV/Visible spectrophotometer with Colour Touchscreen, USB interface for data/method storage, Built in Printer and Bluetooth accessory. Double beam
Specification | Data |
---|
Type | UV/Vis | Wavelength Range | 190 - 1100nm | Wavelength Accuracy (+/-) | ± 0.3nm across wavelength range (at 1nm bandwidth) | Wavelength Reproducibility (+/-) | ± 0.1nm (at 1nm bandwidth) | Lamp Source | Deuterium/Tungsten | Beam | Double Beam | Optical System | Czerny-Turner Monochromator | Bandwidth | Variable (0.5nm, 1nm, 2nm, 4nm) | Detector | Dual Solid State Silicon photodiode | Photometric Range | -4.000A to 4.000A | Stray Light | <0.025%T at 220nm (NaI), <0.025%T at 340nm (NaNO2), <1%T at 198nm & 200nm (KCl) (at 1nm bandwidth) | Zero Stability | ± 0.0003A/hr at 500nm in precision mode (at 1nm bandwidth) | Baseline Flatness | ± 0.001A 220 to 900nm (at 1nm bandwidth) | Measurement Type | Fixed Wavelength, Abs/%T, Abs ratio, Abs difference, concentration (standard curve), concentration (factor), multiwavelength, kinetics, Life Science Methods, user log-on, Equation editor | Cell Compatibility | Cuvette, Microcell*, Variable Pathlength Cell* | Other Sample Containers | Test Tube* | Cell Holder | Dual (sample and reference), 8 cell changer*, 5 position heated cell changer*, variable pathlength cell holder* | Accessory Options | Film holder* | Temperature Control | Temperature controlled cell changer*, Water Jacket* | Method Storage | Up to 90 on-board, unlimited via USB | Regulatory Compliance | European Pharmacopoeia, IQ/OQ*, 21CFR part 11* | Printer | Built in Thermal*, External via Export* | Data Output | Store, Print*, USB Drive*, Export to PC, PC Control* | Display | Colour Touchscreen | Export/ Data Storage | Internal Memory, USB Drive*, Bluetooth*, USB cable to PC | Data Interface | USB | Languages | English, French, German, Spanish | Power Requirement | 85-264 V (150 VA) | Weight | 18Kg (39.7lb) | Dimensions (WxDxH) | 535 x 440 x 335mm (21.3 x 18.1 x 13.2 inches) | Certification | CE | Noise | <0.002A peak to peak, 0.0005A RMS near 2A at 500nm. <0.00005A RMS at 0A at 500nm over 20 measurements (at 1nm bandwidth) | Photometric Accuracy | ± 0.002A at 0.5A, ± 0.004A at 1A, ± 0.006A at 2A at 440nm, 456nm, 546.1nm, 590nm, 635nm ± 0.005A using 60mg/L K2Cr2O7 | Photometric Reproducibility | ± 0.002A at 1A (at 1nm bandwidth) | Scan Speed | >2400 nm/min | Spectral Scanning | Yes (up to 1100nm) |
Designed for busy multi-user laboratories The Biochrom Libra S80 model is s robustly designed to deliver reliable, low maintenance UV/Visible spectrophotometry in environments with multiple users in a regulated environment such as method development. Users can quickly and easily walk up to the instrument, set up a sample, select the appropriate measurement protocols and collect the results. Results and methods can be stored on board or the convenient USB port enables individual users to load personal methods and transport data. 21CFR Part 11 compliance via the optional Resolution software.
Easy to use Colour touch screen user interface with menu driven software and simple intuitive icons is easy to both use and to learn. Results can be easily transported to a remote PC by memory stick for analysis later, or link to a PC directly with PVC software (included). Full PC control with Resolution software
Built in Software Full suite of software applications provided as standard with real choice of data export methods. Trace Manager enables you to manipulate data stored on the instrument or USB memory stick. Multi level User log on facility allows supervisors to restrict access to software functionality allowing secure methods to be set up. Software Modules Function Single Wavelength Measurement Fixed wavelength, Abs/%T, and Concentration (factor) Wavelength Scanning Sample overlays, automatic feature detection and post run data manipulation Concentration Standard Curve Quantitation using calibration curves with multiple standards and a choice of curve fits Kinetics Serial (or parallel measurements with optional cell changer) including sample overlays and post run data manipulation Life Science Methods DNA, RNA & Oligo concentration and purity measurement with optional wavelength scanning. CyDyeTM DNA quantitation. Tm calculation. Protein concentration by direct UV measurement or Bradford, Biuret, Lowry or BCA colorimetric methods Equation Editor Turn your instrument into a "custom application analyzer" by setting up stored methods including calculations based on measured sample data, for example: Absorbance difference and ratios.
Easy to Connect Two USB ports are provided as standard. One is conveniently located by the user touchscreen to enable USB memory sticks (flash drives) to be be used to both store data and methods in secure and ASCII formats. Particularly useful for laboratories wishing to clone methods between multiple instruments. The other USB port is on the side of the instrument is used for PC communication, control, software update and print via computer (PVC). All stand-alone Biochrom Libra instruments offer users a choice in export and print functionality with selection parameters stored as part of any method.
Export to PC via USB cable (standard) Built in printer (optional) Export to a PC via Bluetooth (optional) Full PC control with Resolution Software (included)
Resolution PC Software Supplied with the Biochrom Libra S80 Resolution PC software offers users extra flexibility on data collection and manipulation. Resolution has the power to work in the way you want and includes modules for fixed wavelength, wavelength scanning, kinetics and quantitation measurements plus a validation routine for checking instrument performance. Data export options include Microsoft� Word and Excel� plus Adobe� PDF formats. Optional upgrade modules are also available including Resolution Life for Nucleic Acid and protein measurement and Resolution CFR for 21 CFR part 11 compliance.
Superb Optical Design High energy throughput double beam optical system with variable bandwidth (0.5nm, 1nm, 2nm, 4nm) gives users the flexibility and performance to measure demanding sample types whilst ensuring EP compliance.
Cell Holders The Biochrom Libra S80 is supplied with 10mm pathlength cell holders in sample and reference positions.
Accessories The sample compartment is designed for use with a wide range of accessories. All are designed to be easily changed by users with the minimum of tools. See Biochrom Libra Double Beam Accessories for a full list of optional accessories with order codes.
|